Exendis Impulse Uživatelský manuál Strana 16

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 27
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 15
EXENDIS B.V.
Impulse Peak Power Pack
Impulse Peak Power PackImpulse Peak Power Pack
Impulse Peak Power Pack
16
6.3 Connection of the inp ut (+ DC in -)
A 12Vdc voltage supply can be connected to the
input connection (3+ and 3- fastons), such as a 12V
car voltage (so that the Impulse Peak Power Pack is
charged from the car dynamo/battery) or a 12Vdc
solar panel.
The wires to this connection must be fetched twice
through the supplied ferrite ring to prevent that the
Impulse Peak Power Pack during charge might
cause radio jam. The ferrite ring must be located
close to the Impulse Peak Power Pack.
6.4 Connection of an exte rnal push button
An external push button can be connected to the input connection (4a and 4b fastons).
This can be useful if the Impulse Peak Power Pack is mounted out of easy reach. This
external push button must be normally open.This push button has the same function as
the internal push button near the LEDs.
Pay attention, that if the external push button is constantly switched on, and the Impulse
Peak Power Pack switches off automatically, the Impulse Peak Power Pack will not react
anymore on the push button (neither external, nor internal push button)
The Impulse Peak Power Pack can be switched on again by switching off (or
disconnecting) the external push button and wait for 5 minutes. Than the Impulse Peak
Power Pack will react normally on the push buttons again. An other possibility is
connecting/switching on an input voltage (at Dcin).
7. TAKING THE IMPULSE PEAK POWER PACK INTO OPERATION
If an input voltage is present at the “DC in” (power adapter or fastons input), the Impulse
Peak Power Pack will automatically start charging. If the input voltage is interrupted (or a
failure occurs), charging will be stopped automatically.
The output voltage can be switched on by the push button.
The push button beside the LEDs has two functions:
Switch the output voltage on/off. (If the output voltage is switched off during charge
process, the charge process will continue.)
Clear a failure, that is being indicated by blinking LEDs.
(The external push button has the same function as the internal push button near the
LEDs.)
If there is no input voltage and the output current is lower than 1A for 15 minutes, the
Impulse Peak Power Pack will automatically switch off the output voltage.
(Switch off by the push button is also possible of course.)
8. INDICATIONS