2. DESIGN / SPECIFICATIONS
Primary voltage : 230 Vac - 50/60 Hz - 1-phase
Secondary nominal voltage : 12V or 24V *)
Secondary maximum voltage : 35 V
Secondary current : max. 12 A for Impulse S 12 *)
max. 16 A for Impulse S 16 *)
Battery type : Lead acid: Gel/Wet/AGM *)
Battery capacity : *)
Min. Max.
(in order to charge
80% capacity
Within 8 hours)
Impulse S12 80 Ah 125 Ah
Impulse S16 120 Ah 165 Ah
Protective devices : - protected against reversed polarity
- protected against high temperatures
Input power 450 W with Impulse S12
600 W with Impulse S16
Efficiency : min. 80% (at full load)
Ambient temperature : 0 °C to +40 °C
Dimensions cabinet : Height 80 x Width 180 x Depth 220 mm
Safety class : II
International Protection class : IP 21
Overall weight : 1.6 kg
Transport and storage
Ambient temperature storage : -15°C … +50°C.
Relative air humidity max. : 90 %
(non condensing)
*) can be set by the supplier/dealer
3. SAFETY INSTRUCTIONS
Carefully read the manual and the Safety Instructions.
The IMPULSE S should never be exposed to the rain or be stored in a humid room.
The IMPULSE S is exclusively for indoor application.
Explosion hazard!
Avoid sparking or fire in the immediate environment of the battery.